Watch the videos of the generators in stock in Kinshasa. We will be receiving other models between 10 and 500 kVA in the coming weeks.
Don't hesitate to contact us for more information.
P250-5 FG Wilson
FG Wilson P250-5 generator video
Generator Specifications
| Minimum rated characteristic | 230 kVA / (184 kW) |
| Maximum rated characteristic | 250 kVA / (200 kW) |
| Anti-pollution/fuel-saving strategy | Optimising fuel consumption |
| Prime 50 Hz | 230 kVA / (184 kW) |
| Backup 50 Hz | 250 kVA / (200 kW) |
| Frequency | 50 Hz |
| Speed | 1,500 rpm |
| Voltage | 115-400 V |
Engine Specifications
| Engine model | Perkins® 1506A-E88TAG2 |
| Bore | 112 mm (4.4 in) |
| Race | 149 mm (5.9 in) |
| Type of controller | Electronics |
| Displacement | 8.8 (57.0 in3) |
| Compression ratio | 16.1:1 |
P110-3 FG Wilson
Generator Specifications
| Minimum rated characteristic | 100 kVA / 80 kW |
| Maximum rated characteristic | 125 kVA / 100 kW |
| Anti-pollution/fuel-saving strategy | Optimising fuel consumption |
| Prime 50 Hz | 100 kVA / 80 kW |
| Backup 50 Hz | 110 kVA / 88 kW |
| Priming 60 Hz | 113 kVA / 90.4 kW |
| Backup 60 Hz | 125 kVA / 100 kW |
| Frequency | 50 / 60 Hz |
| Speed | 1500 or 1800 rpm |
| Voltage | 110-480 V |
| Starting power 50 Hz | These powers are suitable for a continuous supply of electrical energy (variable load) in place of mains electricity. There are no restrictions on annual operating hours and this model can provide an overload power of 10 % for 1 hour over a 12-hour period. |
| Prime power 60 Hz | These powers can be used to provide a continuous power supply (with variable load) in the event of a mains power failure. These ratings do not allow overloading. The alternator on this model is rated for peak continuous power (ISO 8528-3 definition). |
| Standby power 50 Hz | Standard reference conditions: air inlet temp. 25°C (77°F), 100 m (328 ft) above sea level, 30 % relative humidity. Fuel consumption data at full load, using diesel fuel with a specific gravity of 0.85 and in accordance with BS2869: 1998, Class A2. |
Engine Specifications
| Engine model | Perkins® 1104C-44TAG2 |
| Bore | 105 mm (4.1 in) |
| Race | 127 mm (5 in) |
| Type of controller | Electronics |
| Displacement | 4.4 l (268.5 in3) |
| Compression ratio | 18.3:1 |
P88-3 FG Wilson
Generator Specifications
| Minimum rated characteristic | 80.0 kVA / 64.0 kW |
| Maximum rated characteristic | 100.0 kVA / 80.0 kW |
| Anti-pollution/fuel-saving strategy | Optimising fuel consumption |
| Prime 50 Hz | 80.0 kVA / 64.0 kW |
| Backup 50 Hz | 88.0 kVA / 70.4 kW |
| Priming 60 Hz | 90.0 kVA / 72.0 kW |
| Backup 60 Hz | 100.0 kVA / 80.0 kW |
| Frequency | 50 / 60 Hz |
| Speed | 1500 or 1800 rpm |
| Voltage | 110-480 V |
| Starting power 50 Hz | These powers are suitable for a continuous supply of electrical energy (variable load) in place of mains electricity. There are no restrictions on annual operating hours and this model can provide an overload power of 10 % for 1 hour over a 12-hour period. |
| Prime power 60 Hz | These powers can be used to provide a continuous power supply (with variable load) in the event of a mains power failure. These ratings do not allow overloading. The alternator on this model is rated for peak continuous power (ISO 8528-3 definition). |
| Standby power 50 Hz | Standard reference conditions: air inlet temp. 25°C (77°F), 100 m (328 ft) above sea level, 30 % relative humidity. Fuel consumption data at full load, using diesel fuel with a specific gravity of 0.85 and in accordance with BS2869: 1998, Class A2. |
Engine Specifications
| Engine model | Perkins® 1104A-44TG2 |
| Bore | 105 mm (4.1 in) |
| Race | 127 mm (5 in) |
| Type of controller | Mechanical engineering |
| Displacement | 4.4 l (268.5 in3) |
| Compression ratio | 17.25:1 |