Description
- Minimum rating : 20.0 kVA / 16.0 kW
- Maximum rating : 22.0 kVA / 17.6 kW
- Anti-pollution/fuel-saving strategy : Optimising fuel consumption
Overview
6.8-25kVA
The 6.8 - 25 kVA range of generator sets is designed to meet all your power requirements. With a wide choice of power nodes, this range is designed for optimum performance in a variety of applications, including construction, residential, retail and telecommunications. The contemporary design of the polymer enclosure option redefines longevity in the market and also enhances this range with the more traditional metal enclosure. For uninterrupted operation, trust FG Wilson.
Benefits
Up to 2000L - Large-capacity fuel tank
The larger fuel tank means longer refuelling intervals.
As Low As 57 dBA Super silent enclosures
Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m
Telematics-ready - Stay in control
The telematics functionality allows remote access to the generator set controls so you can stay in control, wherever you are.
History
The 6.8 - 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.
Industry Leading Perkins Engine
Perkins 400 Series engines, compliant with the EUIIIa emissions standard on selected nodes, offer exceptional performance as well as low fuel consumption. These engines have been designed and field proven for a wide range of applications. They are reliable and also offer low operating costs and excellent energy efficiency.
Alternator
Known around the world for providing power generation expertise and solutions that deliver long-life, FG Wilson FGL and Leroy Somer low-maintenance products. With excellent performance and engine starting capabilities, these alternators have been designed specifically to work with the FG Wilson generator set.
FG100 Control Panel
The FG 100 control panel makes it easy to control the generator set. Key information is displayed on the LCD screen using universal symbols, eliminating the need for complex instructions or language settings. RainbowSCADA PC software allows remote control of your generator set.
Testing and Validation
Fully prototype tested with certified torsional vibration analysis available
Worldwide After-Sales Service
FG Wilson manufactures its products in the following countries: Brazil – China – India. Headquartered in Northern Ireland, FG Wilson operates through a global dealer network.
Cooling System
Designed to operate in ambient temperatures up to 55 C
Generator set specifications
| Minimum rated characteristic | 20.0kVA / 16.0 kW |
| Maximum rated characteristic | 22.0kVA / 17.6 kW |
| Anti-pollution/fuel-saving strategy | Optimising fuel consumption |
| Prime 50 Hz | 20.0kVA / 16.0 kW |
| Backup 50Hz | 22.0kVA / 17.6 kW |
| Prime 60Hz | – / – |
| Backup 60 Hz | – / – |
| Frequency | 50 Hz |
| Speed | 1500rpm |
| Voltage | 220-415V |
| Prime power 50 Hz | These powers are suitable for a continuous supply of electrical energy (variable load) in place of mains electricity. There are no restrictions on annual operating hours and this model can provide an overload power of 10 % for 1 hour over a 12-hour period. |
| Prime power 60 Hz | These powers can be used to provide a continuous (variable load) power supply in the event of a mains power failure. These ratings do not allow overloading. The alternator on this model is rated for continuous peak power (ISO8528-3 definition). |
| Standby power 50Hz | Standard reference conditions: air inlet temp. 25°C (77°F), 100m (328ft) above sea level, 30 % relative humidity. Fuel consumption data at full load, using diesel fuel with a specific gravity of 0.85 and in accordance with BS2869: 1998, Class A2. |
Engine specifications
| Engine model | Perkins® 404A-22G1 |
| Bore | 84.0mm (3.3in) |
| Race | 100.0mm (3.9in) |
| Type of controller | Mechanical engineering |
| Displacement | 2.2l (135.2 in3) |
| Compression ratio | 23.3:1 |
STANDARD EQUIPMENT
ENGINE
- Air filter
- Lube oil drain
- Engine filled with lubricating oil
- Stop due to high coolant temperature
- Stop due to insufficient oil pressure
COOLING
- Radiator assembly
- Radiator and cooling fan
- Coolant drain cock
- Fan, fan drive and battery charging alternator fully protected to comply with EC Machinery Directives
- Cooling system filled with coolant mixture
EXHAUST
- Exhaust flange outlet
- Exhaust pipe and gasket
FUEL
- 8h fuel tank or skid base
- Fuel connections for local or remote supply
ALTERNATOR
- FG Wilson alternator
- DERIVATIVE excitation
- IP23 protection
CONTROL PANEL
- DSE4520
- FG100
MOUNTING
- Skid base, formed steel
- Base, formed steel with skid base or single-wall fuel tank
- Certified lifting eyes on the base, pulling eyes at the rear
- Anti-vibration silencers
- Battery Tray and Cables
P22-1 OPTIONS
EXHAUST
- Industrial, residential and critical silencers
ALTERNATOR
- Leroy Somer alternator
- Quadrature droop kit
- Anti-condensation heater and control panel circuit
CONTROL PANELS
- DSE4520
- DSE7320
- DSE7410
- DeepSeaDSE7420
GENERAL
- 8h, 600l, 1000l, 2000l fuel tanks
- Upgrade to standard genset for CE certification
- EEC Declaration of Conformity
- Narrow, wide or skid base
- Soundproof steel or galvanised enclosure
- Double-walled fuel tanks
STARTING/CHARGING
- Dry acid battery
CAPTURE
- Compliance with European Community Directive 2000/14/EC
- High soundproofing for residential areas
- Fully enclosed heavy-duty exhaust silencer system
- Robust, highly corrosion-resistant construction