FG Wilson P110-3 (110 kVA) generator set

Key specifications

Minimum rating : 100 kVA / 80 kW
Maximum rating : 110 kVA / 88 kW
Anti-pollution/fuel-saving strategy : Optimising fuel consumption

Description

Minimum rating : 100.0 kVA / 80 kW
Maximum rating : 125 kVA / 100 kW
Anti-pollution/fuel-saving strategy : Optimising fuel consumption

Overview

24 - 220 kVA

The 24 - 220 kVA range provides reliable power for today's world with a competitive offering that delivers everything you need. Providing unrivalled quality, the 24 - 220 kVA range of products offers a trusted performance with an enhanced choice of options, optimising the range for a variety of diverse applications and environments. Designed with the demands of today's world in mind, this range will deliver power solutions in all sectors, from industry and retail to finance and healthcare

Benefits

Low running costs - Fuel Optimised

Designed to deliver optimal fuel economy

Enhanced choice of options

Optimising the range for a variety of diverse applications and environments

History

History

The 24 - 220 kVA range provides reliable power for today's world with a competitive offering that delivers everything you need. Providing unrivalled quality, the 24 - 220 kVA range of products offers a trusted performance with an enhanced choice of options, optimising the range for a variety of diverse applications and environments. Designed with the demands of today's world in mind, this range will deliver power solutions in all sectors, from industry and retail to finance and healthcare.

Industry Leading Perkins Engine

State-of-the-art Perkins engine

The Perkins 1100 Series engines offer highly competitive performance, fuel economy and EUIIIa Emissions compliance on selected nodes. These engines have been designed and proven in the field in a wide variety of applications. With low fuel and oil consumption, and 500 hour service intervals, the 1100 series engine will run and run.

Alternator

Alternator

Benefiting from a choice of leading alternators, the FG Wilson FGL and Leroy Somer brand alternators are known worldwide for providing power generation expertise and solutions offering longlife products with low maintenance. Offering excellent performance and motor starting capacility they have been designed specifically to suit the FG Wilson generator set.

FG 100 Control Panel

FG100 control panel

The FG Wilson FG100 allows you to monitor and control your generator set with ease, providing important diagnostic information whilst ensuring your unit operates within safe parameters. FG Wilson FG100 control panels, provide simple, intuitive menu navigation and control of your generator set operations. Key information is displayed via the LCD screen and LED's using universally recognised symbols, eliminating the need for complex instructions or language settings.

Testing and validation

Testing and validation

Fully prototype tested with certified torsional vibration analysis available

Worldwide After-Sales Service

Worldwide after-sales service

FG Wilson manufactures product in the following locations: Brazil - China - India With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.

Generator set specifications

Minimum rated characteristic 100kVA / 80 kW
Maximum rated characteristic 125kVA / 100 kW
Anti-pollution/fuel-saving strategy Optimising fuel consumption
Prime 50 Hz 100kVA / 80 kW
Backup 50Hz 110kVA / 88 kW
Prime 60Hz 113kVA / 90.4 kW
Backup 60 Hz 125kVA / 100 kW
Frequency 50 / 60 Hz
Speed 1500 or 1800 rpm
Voltage 110-480V
Prime power 50Hz These powers are suitable for a continuous supply of electrical energy (variable load) in place of mains electricity. There are no restrictions on annual operating hours and this model can provide an overload power of 10 % for 1 hour over a 12-hour period.
Prime power 60 Hz These powers can be used to provide a continuous (variable load) power supply in the event of a mains power failure. These ratings do not allow overloading. The alternator on this model is rated for continuous peak power (ISO8528-3 definition).
Standby power 50Hz Standard reference conditions: air inlet temp. 25°C (77°F), 100m (328ft) above sea level, 30 % relative humidity. Fuel consumption data at full load, using diesel fuel with a specific gravity of 0.85 and in accordance with BS2869: 1998, Class A2.

ENGINE SPECIFICATIONS

Engine model Perkins® 1104C-44TAG2
Bore 105mm (4.1in)
Race 127 mm (5 in)
Type of controller Electronics
Displacement 4.4l (268.5 in3)
Compression ratio 18.3:1

STANDARD EQUIPMENT

ENGINE

  • Air filter
  • Lube oil drain
  • Engine filled with lubricating oil
  • Stop due to high coolant temperature
  • Stop due to insufficient oil pressure

COOLING

  • Radiator assembly
  • Radiator and cooling fan
  • Coolant drain cock
  • Fan, fan drive and battery charging alternator fully protected to comply with EC Machinery Directives
  • Cooling system filled with coolant mixture

EXHAUST

  • Exhaust flange outlet
  • Exhaust pipe and gasket

FUEL

  • 8h fuel tank
  • Fuel connections for local or remote supply

ALTERNATOR

  • FG Wilson FGL alternator
  • DERIVATIVE excitation
  • IP23 protection

CONTROL PANEL

  • DCP-10

MOUNTING

  • Base, formed steel with skid base or single-wall fuel tank
  • Certified lifting eyes on the base, pulling eyes at the rear
  • Anti-vibration silencers
  • Battery Tray and Cables

 

OPTIONS

EXHAUST

  • Industrial, residential and critical silencers

ALTERNATOR

  • Leroy Somer alternator
  • Quadrature droop kit
  • Anti-condensation heater and control panel circuit

CONTROL PANELS

  • PowerWizard1.1 (PWT1.1) Control Panel
  • PowerWizard1.1 (PWT1.1) Control Panel
  • PowerWizard2.1 (PWT2.1) Control Panel

STARTING/CHARGING

  • Dry acid battery

GENERAL

  • Upgrade to standard genset for CE certification
  • EEC Declaration of Conformity
  • Narrow, wide or skid base
  • Soundproof steel or galvanised enclosure
  • Double-walled fuel tanks

CANOPY

  • Compliance with European Community Directive 2000/14/EC
  • High soundproofing for residential areas
  • Fully enclosed heavy-duty exhaust silencer system
  • Robust, highly corrosion-resistant construction

PDF

Contact us

⚡️ 🔌💡⛽️⚙️

Contact us today to find out if the product is in stock and to obtain a competitive quotation via the form below or by phone. WhatsApp (+243 81 99 35 000).